Summary

DxCMonitor service fails to start because of a time-out error in Service Control Manager.

Information

After reboot the DxCMonitor service fails to start and the following Service Control Manager errors are logged in the System Event Log.

Log Name:      System
Source: Service Control Manager
Date: 8/24/2017 10:55:39 AM
Event ID: 7022
Task Category: None
Level: Error
Keywords: Classic
User: N/A
Computer: Node1-w2k8r2
Description:
The DxCMonitor service hung on starting.
Log Name:      System
Source: Service Control Manager
Date: 8/24/2017 10:55:40 AM
Event ID: 7001
Task Category: None
Level: Error
Keywords: Classic
User: N/A
Computer: Node1
Description:
The DxLMonitor service depends on the DxCMonitor service which failed to start because of the following error:
After starting, the service hung in a start-pending state.

Resolution

Follow Microsoft's recommendation to resolve the issue.